Low-voltage switchboards and switchgear
Main switchboards, distribution sections and motor control centres: cleaned, torqued, tested for insulation and contact resistance, with every breaker and switch operated.
Switchgear testing
We test and service low- and medium-voltage switchgear, switchboards and transfer switches during planned shutdowns, and check energized gear with infrared and ultrasound in between. Red Seal electricians and protection technicians, results on field test sheets against manufacturer and NETA limits. Halifax and Calgary crews, serving sites across Canada.
At a glance
Switchgear testing checks that low- and medium-voltage gear is safe to operate and will clear a fault. Energized gear is checked with infrared and ultrasound; during a planned shutdown we test insulation and contact resistance, relays and breakers, then clean and torque.
What we test
From low-voltage switchboards and MCCs to medium-voltage metal-clad switchgear.
Main switchboards, distribution sections and motor control centres: cleaned, torqued, tested for insulation and contact resistance, with every breaker and switch operated.
Bus, compartments and breakers serviced to the manufacturer's instructions, with breaker testing and protective relay checks in the same outage.
Transfer switches inspected and operated, with controller settings recorded and a planned transfer test, so emergency power is there when the normal supply fails.
Relay settings captured as found and as left, wiring and status validated, and trip functions tested against the settings.
Tests and service
The exact list follows the equipment and its manufacturer's instructions. A typical program covers:
What you receive
Every section gets a completed field test sheet: nameplate, as-found condition, measured values against the limits and what was done. A deficiency log lists what failed and what to do about it, so your electricians can schedule repairs.
Results are kept in the same format year to year, so a bus joint whose resistance is creeping up is caught before it overheats.
How it works
Share the single-line, the equipment list and any manuals or past test reports. We reply with a test program and quote within one business day.
Test sheets are prepared from the manufacturer's instructions before we arrive. Outage windows are agreed in advance, and we often scan the energized gear first so the outage fixes what the scan found.
Red Seal electricians and protection technicians test as found, service, then test as left. Urgent deficiencies are reported to your site contact before we leave, and the report comes with the completed test sheets and a deficiency log.
What you receive
Every DTI breaker and relay job is documented on field test sheets like these: nameplate and as-found condition, contact resistance, insulation resistance, timing and trip tests against the manufacturer and NETA limits, relay settings captured as-found and as-left, and a deficiency log your electricians can work from. This is a complete sample set with the client fields blank.
Where we work
Crews are based in Halifax and Calgary and service industrial, commercial, healthcare and institutional sites anywhere in Canada, anytime, including remote and northern sites.
All electrical testing servicesCleaning, torque checks and insulation and contact resistance tests need the gear de-energized and isolated. Infrared scans and ultrasound checks are done while the gear is energized and carrying its normal load, so we often do those first and use the outage to fix what they found.
Intervals depend on the equipment's condition, how critical it is and its environment, as CSA Z463 describes. Many sites scan energized gear with infrared every year and schedule de-energized maintenance less often, at planned outages.
Yes, some of them. Infrared finds hot connections under load, and airborne ultrasound can hear partial discharge inside sealed medium-voltage gear. See our partial discharge case study. Insulation and contact resistance still need an outage.
Yes. We service medium-voltage metal-clad switchgear, breakers and protective relays at industrial, mining, healthcare and commercial sites, including remote and northern sites.
It depends on the number of sections and devices and the outage windows. Send the single-line and your preferred dates and we reply with a quote within one business day.
Send us the single-line and the equipment list; we quote the test program within one business day.